.RE
.SP
.B "PORT"
+.RI [ family ]
Emits an
.B INFO
line containing just the number of the UDP port used by the
.B tripe
-server. If you've allowed your server to allocate a port dynamically,
-this is how to find out which one it chose.
+server, for the given address
+.I family
+(or one chosen arbitrarily if omitted -- though
+.B tripe
+tries to use the same port number consistently so this is not a likely
+problem in practice). If you've allowed your server to allocate a port
+dynamically, this is how to find out which one it chose.
.SP
.B "RELOAD"
Instructs the server to recheck its keyring files. The server checks
The attempt to send a ping packet failed, probably due to lack of
encryption keys.
.SP
+.B "provider-failed"
+(For
+.BR SVCSUBMIT .)
+The service provider disconnected without sending back a final reply to
+the job.
+.SP
+.B "provider-overloaded"
+(For
+.BR SVCSUBMIT .)
+The service provider has too many jobs queued up for it already.
+.SP
.BI "resolve-error " hostname
(For
.BR ADD .)
.I tag
is already the tag of an outstanding job.
.SP
+.BI "unknown-address-family " afam
+(For
+.BR PORT .)
+The address family
+.I afam
+is unrecognized.
+.SP
.BI "unknown-command " token
The command
.I token
.I tag
is not the tag for any outstanding background job. It may have just
finished.
+.SP
+.BI "unknown-tunnel " tun
+(For
+.BR ADD .)
+The given
+.I tun
+is not the name of any known tunnel driver.
.
.\"--------------------------------------------------------------------------
.SH "NOTIFICATIONS"
match any outstanding ping. Maybe it was delayed for longer than the
server was willing to wait, or maybe the peer has gone mad; or maybe
there are bad people trying to confuse you.
+.SS "PRIVSEP warnings"
+These indicate problems with the privilege-separation helper process.
+(The server tries to drop its privileges when it starts up, leaving a
+privileged helper process behind which will create and hand over tunnel
+descriptors on request, but hopefully not do anything else especially
+dangerous. Tunnel descriptors are not completely safe, but this is
+probably better than nothing.)
+.SP
+.BI "PRIVSEP child-exited " rc
+The helper process exited normally with status
+.IR rc .
+Status 0 means that it thought the server didn't want it any more; 1
+means that it was invoked incorrectly; 127 means that some system call
+failed.
+.SP
+.BI "PRIVSEP child-killed " sig
+The helper process was killed by signal number
+.IR sig .
+.SP
+.BI "PRIVSEP child-died " status
+The helper process died in some unexpected way;
+.I status is the raw status code returned by
+.BR waitpid (2),
+because the server didn't understand how to decode it.
+.SP
+.BI "PRIVSEP helper-died"
+A tunnel driver requires a tunnel descriptor from the helper, but the
+helper isn't running so this won't work.
+.SP
+.BI "PRIVSEP helper-read-error " ecode " " message
+The server failed to read a response from the helper process.
+.SP
+.BI "PRIVSEP helper-short-read"
+The helper process didn't send back enough data, and has likely crashed.
+.SP
+.BI "PRIVSEP helper-write-error " ecode " " message
+The server failed to send a message to the helper process.
+.SP
+.BI "PRIVSEP no-fd-from-helper"
+The helper process sent back a positive response, but didn't include the
+requested tunnel descriptor.
+.SP
+.BI "PRIVSEP unknown-response-code"
+The helper process sent back an incomprehensible reply. It's probably
+very confused and may crash.
.SS "SERVER warnings"
These indicate problems concerning the server process as a whole.
.SP
.BI "SERVER select-error " ecode " " message
An error occurred in the server's main event loop. This is bad: if it
happens too many times, the server will abort.
+.SP
+.BI "SERVER waitpid-error " ecode " " message
+The server was informed that one of its child processes had exited, but
+couldn't retrieve the child's status.
.SS "SYMM warnings"
These are concerned with the symmetric encryption and decryption
process.